LED Wattage Equivalent & Conversion Chart

By LEDaBulb Editorial Team • Updated November 12, 2026

As an Amazon Associate, we earn from qualifying purchases. Recommendations never depend on commission rates.

Affiliate Disclosure: When you buy through our links, we may earn a commission at no extra cost to you. That supports our specification database and calculators.

Selection Methodology: Picks come from verified manufacturer data sheets, certification databases (DesignLights Consortium QPL for commercial fixtures, California Title 24 JA8, FTC Lighting Facts, and EPA ENERGY STAR for recessed downlights), and owner failure-rate analysis. We do not run hands-on lab tests.

Match any incandescent, halogen, CFL, fluorescent tube, metal halide, or HPS lamp to its verified LED wattage and lumen output, or look up what incandescent bulb an unmarked LED replaces.

Quick Household Reference: 40W = 5–6W LED (450 lm) · 60W = 8–9W LED (800 lm) · 75W = 10–12W LED (1,100 lm) · 100W = 14–16W LED (1,600 lm) · 150W = 20–25W LED (2,600 lm). Match lumens for equal brightness, and check voltage or ballast rules before swapping 12V halogens, linear tubes, or commercial HID lamps.

Old Bulb to LED Replacement Chart

Filter by bulb type or type any wattage below. Select View ROI for socket and wiring details or Find Bulb to browse verified replacements.

LED Watts → Incandescent ↓
Old Bulb LED Replacement Brightness Action

Incandescent & Household Floods

Standard E26 household bulbs, E12 candelabra bulbs, BR30/PAR38 floods, and 3-way table lamp bulbs. Cuts power draw by 82–87%.

15W Incandescent (Appliance / E12) 1.5–2W LED 110 lm
25W Incandescent (E12 Candelabra) 3–4W LED 225 lm
40W Incandescent (A19 / G25) 5–6W LED 450 lm
60W Incandescent (A19 E26) 8–9W LED 800 lm
65W BR30 Flood (6-in Recessed Can) 9–11W LED 650–850 lm
75W Incandescent (A19 E26) 10–12W LED 1,100 lm
90W PAR38 Flood (Outdoor E26) 12–15W LED 1,200–1,350 lm
100W Incandescent (A19 / A21) 14–16W LED 1,600 lm
150W Incandescent (A21 E26) 20–25W LED 2,600 lm
200W Incandescent (A21 / Utility) 25–30W LED 3,200 lm
30/70/100W 3-Way (A19 E26d) 4 / 9 / 15W LED 400 / 900 / 1,600 lm
50/100/150W 3-Way (A21 E26d) 6 / 14 / 21W LED 600 / 1,600 / 2,200 lm

Halogen

Quartz-halogen spots and floods (12V MR16 GU5.3, 120V GU10, E26 PAR, and R7s J-type). Verify voltage and pin/screw base before ordering.

20W Halogen (MR16 / G4 12V) 3W LED 230 lm
35W Halogen (MR16 / GU10) 5–6W LED 450 lm
50W Halogen (GU10 / PAR20) 7–9W LED 675 lm
75W Halogen (PAR30 E26) 10–12W LED 1,050 lm
100W Halogen (PAR38 E26) 13–16W LED 1,500 lm
150W Halogen (PAR38 / Flood) 20–25W LED 2,400 lm
300W Halogen (R7s J-Type) 35–45W LED 4,750 lm
500W Halogen (R7s 118mm) 60–80W LED 8,750 lm

CFL (Compact Fluorescent)

Spiral E26 bulbs (9–23W) and commercial 2-pin/4-pin G24/GX24q PL lamps (26–42W). Contains mercury; recycle spent lamps properly.

9W CFL (E26 Spiral, 40W eq.) 5–6W LED 450 lm
13W CFL (E26 Spiral, 60W eq.) 8–9W LED 800 lm
18W CFL (E26 Spiral, 75W eq.) 10–12W LED 1,100 lm
23W CFL (E26 Spiral, 100W eq.) 14–16W LED 1,600 lm
26W CFL (G24d / G24q Pin) 15–18W LED 1,750 lm
42W CFL (GX24q 4-Pin) 25–30W LED 2,750 lm

Fluorescent Tube

Linear 4-foot T8/T12 (G13 bi-pin) and T5/T5HO (G5 mini bi-pin). Directional LED lumens match 360-degree bare-tube task output.

28W 4-ft T5 Tube (31W w/ ballast) 12–16W LED ~2,000 lm
32W 4-ft T8 Tube (35W w/ ballast) 12–18W LED ~2,100 lm
40W 4-ft T12 Tube (46W w/ ballast) 14–18W LED ~2,100 lm
54W 4-ft T5HO Tube (59W w/ ballast) 24–27W LED ~3,500 lm

Metal Halide

Commercial HID lamps for warehouses, retail, and parking lots. Sized to real-world maintained/delivered lumens after MH lumen depreciation.

70W Metal Halide (90W w/ ballast) 25–35W LED ~4,000 lm
100W Metal Halide (122W w/ ballast) 35–50W LED ~6,000 lm
150W Metal Halide (180W w/ ballast) 60–80W LED ~9,750 lm
175W Metal Halide (210W w/ ballast) 60–80W LED ~10,500 lm
250W Metal Halide (290W w/ ballast) 90–120W LED ~14,500 lm
400W Metal Halide (455W w/ ballast) 130–180W LED ~23,500 lm
1000W Metal Halide (1090W w/ ballast) 300–450W LED ~55,000 lm

High-Pressure Sodium

2100K amber street, yard, and security HID lamps (CRI ~22). Directional white LEDs restore color visibility at 55–65% lower wattage.

70W HPS (92W w/ ballast) 25–40W LED ~4,500 lm
150W HPS (190W w/ ballast) 50–75W LED ~9,000 lm
250W HPS (300W w/ ballast) 90–120W LED ~15,000 lm
400W HPS (465W w/ ballast) 130–200W LED ~24,000 lm
1000W HPS (1095W w/ ballast) 400–500W LED ~63,000 lm
Master LED conversion chart matching lumens (225 to 3,200 lm) across incandescent, halogen, CFL spiral, LED bulbs, and commercial HID lamps Master LED conversion chart matching lumens (225 to 3,200 lm) across incandescent, halogen, CFL spiral, LED bulbs, and commercial HID lamps
Printable LED wattage and lumen equivalence sheet across incandescent, halogen, CFL, tubes, and metal halide. Open full size Vertical Pin (2:3) Download PNG

LED Watts to Incandescent Watts Chart (Reverse Lookup)

Holding an LED bulb stamped 6W, 7W, 9W, or 15W and wondering how bright it is? Use this reverse lookup table to match actual LED wattage to its traditional incandescent or halogen equivalent.

LED Bulb Wattage Incandescent Equivalent Typical Lumens Common Bulb & Fixture
1.5–2W LED 15W Incandescent 100–150 lm E12 nightlights, S14 patio strings, appliances
3W LED 25W Incandescent / 20W Halogen 200–250 lm E12 chandelier candles (B10), 12V G4/MR16 accents
4W LED 25W–35W Incandescent 300–380 lm B11 candelabra sconces, vintage clear filament bulbs
5W LED 40W Incandescent 400–450 lm Ceiling fan light kits, bedside lamps, GU10 spots
6W LED 40W–50W Incandescent 450–550 lm Standard 40W A19 lamps, G25 bathroom vanity globes
7W LED 50W Halogen / 45–50W Inc. 550–675 lm GU10 & PAR20 track heads, 4-inch R20 recessed cans
8W LED 60W Incandescent 750–800 lm High-efficacy A19 table lamps and ceiling domes
9W LED 60W Incandescent 800–850 lm Most common US A19 household bulb & 6-inch BR30 cans
10W LED 60W–65W (or 75W if 1,100 lm) 800–1,050 lm CRI 90+ A19 bulbs (800 lm) or 65W BR30 recessed floods
11–12W LED 75W Incandescent 1,050–1,150 lm Reading lamps, kitchen fixtures, PAR30 indoor floods
13–14W LED 90W–100W Incandescent 1,300–1,600 lm High-efficacy 100W A19 bulbs & PAR38 outdoor floods
15–16W LED 100W Incandescent 1,600 lm CRI 90+ 100W A19/A21 bulbs for lamps, garages, utility
18W LED 32W/40W 4-ft Tube or 100–120W Inc. 1,800–2,100 lm 4-foot T8 LED shop/office tubes & high-output PAR38 floods
20–25W LED 150W Incandescent 2,500–2,700 lm A21 floor lamps, laundry rooms, high-ceiling garages
28–30W LED 200W Incandescent / 70W MH 3,000–4,000 lm Workshops, barn fixtures, E26/E39 corn retrofits

4 Rules to Check Before Buying Your LED Replacement

Matching lumens gets brightness right, while four physical and electrical checks prevent overheating, socket mismatches, and dimmer flicker:

Deep-Dive Conversion Charts by Bulb Family

Open the dedicated conversion hub for your lamp family to compare socket types, transformer or ballast wiring options, and Kelvin recommendations:

Frequently Asked Questions

What is the LED wattage equivalent for a 60-watt incandescent bulb?

An 8W to 9W LED bulb delivering 800 lumens replaces a standard 60W incandescent bulb. Choose 2700K Soft White with CRI 90+ if you want the exact warm glow of an old 60W tungsten filament while cutting electricity use by roughly 85%.

What incandescent wattage is a 9W, 6W, or 15W LED equivalent to?

A 6W LED (450 to 500 lumens) equals a 40W incandescent bulb, a 9W LED (800 lumens) equals a 60W incandescent bulb, and a 15W LED (1,600 lumens) equals a 100W incandescent bulb. If an LED bulb prints 7W (550 to 675 lumens), it typically replaces a 50W halogen spot or a 45W-to-50W incandescent flood.

Can I put a 15W (100W-equivalent) LED bulb in a fixture rated MAX 60W?

Yes in open-air fixtures such as table-lamp harps or open pendants, because the 15W LED draws 75% less electrical power and heat than the socket's 60W thermal limit. In fully enclosed ceiling globes or tight recessed cans, only install bulbs explicitly labeled Suitable for Enclosed Fixtures so trapped heat does not shorten driver life.

How many lumens do I need to replace 40W, 60W, 75W, and 100W bulbs?

Look for 450 lumens to replace 40W, 800 lumens to replace 60W, 1,100 lumens to replace 75W, 1,600 lumens to replace 100W, and 2,600 lumens to replace 150W. If you are planning brightness for a whole room from scratch, use our Room Lumens & Spacing Calculator.

LED Buyer's Guides by Room & Facility

Browse Residential LED Guides (24) or Commercial & Industrial Guides (7):

Residential Room & Fixture Guides

Commercial & Industrial Facility Guides