LED Wattage Equivalent & Conversion Chart
As an Amazon Associate, we earn from qualifying purchases. Recommendations never depend on commission rates.
Affiliate Disclosure: When you buy through our links, we may earn a commission at no extra cost to you. That supports our specification database and calculators.
Selection Methodology: Picks come from verified manufacturer data sheets, certification databases (DesignLights Consortium QPL for commercial fixtures, California Title 24 JA8, FTC Lighting Facts, and EPA ENERGY STAR for recessed downlights), and owner failure-rate analysis. We do not run hands-on lab tests.
Match any incandescent, halogen, CFL, fluorescent tube, metal halide, or HPS lamp to its verified LED wattage and lumen output, or look up what incandescent bulb an unmarked LED replaces.
Old Bulb to LED Replacement Chart
Filter by bulb type or type any wattage below. Select View ROI for socket and wiring details or Find Bulb to browse verified replacements.
| Old Bulb | LED Replacement | Brightness | Action |
|---|---|---|---|
Incandescent & Household FloodsStandard E26 household bulbs, E12 candelabra bulbs, BR30/PAR38 floods, and 3-way table lamp bulbs. Cuts power draw by 82–87%. |
|||
| 15W Incandescent (Appliance / E12) | 1.5–2W LED | 110 lm | |
| 25W Incandescent (E12 Candelabra) | 3–4W LED | 225 lm | |
| 40W Incandescent (A19 / G25) | 5–6W LED | 450 lm | |
| 60W Incandescent (A19 E26) | 8–9W LED | 800 lm | |
| 65W BR30 Flood (6-in Recessed Can) | 9–11W LED | 650–850 lm | |
| 75W Incandescent (A19 E26) | 10–12W LED | 1,100 lm | |
| 90W PAR38 Flood (Outdoor E26) | 12–15W LED | 1,200–1,350 lm | |
| 100W Incandescent (A19 / A21) | 14–16W LED | 1,600 lm | |
| 150W Incandescent (A21 E26) | 20–25W LED | 2,600 lm | |
| 200W Incandescent (A21 / Utility) | 25–30W LED | 3,200 lm | |
| 30/70/100W 3-Way (A19 E26d) | 4 / 9 / 15W LED | 400 / 900 / 1,600 lm | |
| 50/100/150W 3-Way (A21 E26d) | 6 / 14 / 21W LED | 600 / 1,600 / 2,200 lm | |
HalogenQuartz-halogen spots and floods (12V MR16 GU5.3, 120V GU10, E26 PAR, and R7s J-type). Verify voltage and pin/screw base before ordering. |
|||
| 20W Halogen (MR16 / G4 12V) | 3W LED | 230 lm | |
| 35W Halogen (MR16 / GU10) | 5–6W LED | 450 lm | |
| 50W Halogen (GU10 / PAR20) | 7–9W LED | 675 lm | |
| 75W Halogen (PAR30 E26) | 10–12W LED | 1,050 lm | |
| 100W Halogen (PAR38 E26) | 13–16W LED | 1,500 lm | |
| 150W Halogen (PAR38 / Flood) | 20–25W LED | 2,400 lm | |
| 300W Halogen (R7s J-Type) | 35–45W LED | 4,750 lm | |
| 500W Halogen (R7s 118mm) | 60–80W LED | 8,750 lm | |
CFL (Compact Fluorescent)Spiral E26 bulbs (9–23W) and commercial 2-pin/4-pin G24/GX24q PL lamps (26–42W). Contains mercury; recycle spent lamps properly. |
|||
| 9W CFL (E26 Spiral, 40W eq.) | 5–6W LED | 450 lm | |
| 13W CFL (E26 Spiral, 60W eq.) | 8–9W LED | 800 lm | |
| 18W CFL (E26 Spiral, 75W eq.) | 10–12W LED | 1,100 lm | |
| 23W CFL (E26 Spiral, 100W eq.) | 14–16W LED | 1,600 lm | |
| 26W CFL (G24d / G24q Pin) | 15–18W LED | 1,750 lm | |
| 42W CFL (GX24q 4-Pin) | 25–30W LED | 2,750 lm | |
Fluorescent TubeLinear 4-foot T8/T12 (G13 bi-pin) and T5/T5HO (G5 mini bi-pin). Directional LED lumens match 360-degree bare-tube task output. |
|||
| 28W 4-ft T5 Tube (31W w/ ballast) | 12–16W LED | ~2,000 lm | |
| 32W 4-ft T8 Tube (35W w/ ballast) | 12–18W LED | ~2,100 lm | |
| 40W 4-ft T12 Tube (46W w/ ballast) | 14–18W LED | ~2,100 lm | |
| 54W 4-ft T5HO Tube (59W w/ ballast) | 24–27W LED | ~3,500 lm | |
Metal HalideCommercial HID lamps for warehouses, retail, and parking lots. Sized to real-world maintained/delivered lumens after MH lumen depreciation. |
|||
| 70W Metal Halide (90W w/ ballast) | 25–35W LED | ~4,000 lm | |
| 100W Metal Halide (122W w/ ballast) | 35–50W LED | ~6,000 lm | |
| 150W Metal Halide (180W w/ ballast) | 60–80W LED | ~9,750 lm | |
| 175W Metal Halide (210W w/ ballast) | 60–80W LED | ~10,500 lm | |
| 250W Metal Halide (290W w/ ballast) | 90–120W LED | ~14,500 lm | |
| 400W Metal Halide (455W w/ ballast) | 130–180W LED | ~23,500 lm | |
| 1000W Metal Halide (1090W w/ ballast) | 300–450W LED | ~55,000 lm | |
High-Pressure Sodium2100K amber street, yard, and security HID lamps (CRI ~22). Directional white LEDs restore color visibility at 55–65% lower wattage. |
|||
| 70W HPS (92W w/ ballast) | 25–40W LED | ~4,500 lm | |
| 150W HPS (190W w/ ballast) | 50–75W LED | ~9,000 lm | |
| 250W HPS (300W w/ ballast) | 90–120W LED | ~15,000 lm | |
| 400W HPS (465W w/ ballast) | 130–200W LED | ~24,000 lm | |
| 1000W HPS (1095W w/ ballast) | 400–500W LED | ~63,000 lm | |
LED Watts to Incandescent Watts Chart (Reverse Lookup)
Holding an LED bulb stamped 6W, 7W, 9W, or 15W and wondering how bright it is? Use this reverse lookup table to match actual LED wattage to its traditional incandescent or halogen equivalent.
| LED Bulb Wattage | Incandescent Equivalent | Typical Lumens | Common Bulb & Fixture |
|---|---|---|---|
| 1.5–2W LED | 15W Incandescent | 100–150 lm | E12 nightlights, S14 patio strings, appliances |
| 3W LED | 25W Incandescent / 20W Halogen | 200–250 lm | E12 chandelier candles (B10), 12V G4/MR16 accents |
| 4W LED | 25W–35W Incandescent | 300–380 lm | B11 candelabra sconces, vintage clear filament bulbs |
| 5W LED | 40W Incandescent | 400–450 lm | Ceiling fan light kits, bedside lamps, GU10 spots |
| 6W LED | 40W–50W Incandescent | 450–550 lm | Standard 40W A19 lamps, G25 bathroom vanity globes |
| 7W LED | 50W Halogen / 45–50W Inc. | 550–675 lm | GU10 & PAR20 track heads, 4-inch R20 recessed cans |
| 8W LED | 60W Incandescent | 750–800 lm | High-efficacy A19 table lamps and ceiling domes |
| 9W LED | 60W Incandescent | 800–850 lm | Most common US A19 household bulb & 6-inch BR30 cans |
| 10W LED | 60W–65W (or 75W if 1,100 lm) | 800–1,050 lm | CRI 90+ A19 bulbs (800 lm) or 65W BR30 recessed floods |
| 11–12W LED | 75W Incandescent | 1,050–1,150 lm | Reading lamps, kitchen fixtures, PAR30 indoor floods |
| 13–14W LED | 90W–100W Incandescent | 1,300–1,600 lm | High-efficacy 100W A19 bulbs & PAR38 outdoor floods |
| 15–16W LED | 100W Incandescent | 1,600 lm | CRI 90+ 100W A19/A21 bulbs for lamps, garages, utility |
| 18W LED | 32W/40W 4-ft Tube or 100–120W Inc. | 1,800–2,100 lm | 4-foot T8 LED shop/office tubes & high-output PAR38 floods |
| 20–25W LED | 150W Incandescent | 2,500–2,700 lm | A21 floor lamps, laundry rooms, high-ceiling garages |
| 28–30W LED | 200W Incandescent / 70W MH | 3,000–4,000 lm | Workshops, barn fixtures, E26/E39 corn retrofits |
4 Rules to Check Before Buying Your LED Replacement
Matching lumens gets brightness right, while four physical and electrical checks prevent overheating, socket mismatches, and dimmer flicker:
- "MAX 60W" socket stickers measure heat, not brightness: A lamp socket stamped MAX 60W limits actual electrical wattage to protect socket insulation. A 100W-equivalent LED draws only 14W to 16W, making it electrically safe inside an open table-lamp harp. Inside a tightly sealed glass ceiling dome, however, trapped heat bakes LED driver electronics unless the bulb is rated for enclosed fixtures.
- Why 8W, 9W, and 10W LEDs all say "60W Equivalent": Different LED chips and color rendering ratings have different efficacy. High-CRI (CRI 90+) bulbs spend extra energy producing accurate reds and skin tones, so a CRI 90+ bulb may draw 9W to 10W to deliver 800 lumens while a basic CRI 80 bulb hits 800 lumens at 8W. Always read the Lumens line on the box.
- Check base code and bulb height on 100W+ upgrades: Standard household lamps use an E26 screw base and an A19 (4.4-inch tall) envelope, whereas many 100W-to-200W equivalents step up to a taller A21 (5.1-inch) body that can hit small lamp harps. Confirm measurements in our Bulb Base Size Chart and Bulb Shape Chart.
- Verify transformers, ballasts, and wall dimmers: Low-voltage 12V MR16 and G4 halogens run on step-down transformers, linear T8/T12/T5 tubes require matching Type A (plug-and-play) vs. Type B (ballast-bypass) wiring, and commercial Metal Halide or HPS lamps require bypassing the magnetic ballast and ignitor before installing a Type B LED. For dimming circuits, pair dimmable LEDs with a CL/LED+ wall switch from our LED Dimmer Compatibility Guide.
Deep-Dive Conversion Charts by Bulb Family
Open the dedicated conversion hub for your lamp family to compare socket types, transformer or ballast wiring options, and Kelvin recommendations:
Frequently Asked Questions
What is the LED wattage equivalent for a 60-watt incandescent bulb?
An 8W to 9W LED bulb delivering 800 lumens replaces a standard 60W incandescent bulb. Choose 2700K Soft White with CRI 90+ if you want the exact warm glow of an old 60W tungsten filament while cutting electricity use by roughly 85%.
What incandescent wattage is a 9W, 6W, or 15W LED equivalent to?
A 6W LED (450 to 500 lumens) equals a 40W incandescent bulb, a 9W LED (800 lumens) equals a 60W incandescent bulb, and a 15W LED (1,600 lumens) equals a 100W incandescent bulb. If an LED bulb prints 7W (550 to 675 lumens), it typically replaces a 50W halogen spot or a 45W-to-50W incandescent flood.
Can I put a 15W (100W-equivalent) LED bulb in a fixture rated MAX 60W?
Yes in open-air fixtures such as table-lamp harps or open pendants, because the 15W LED draws 75% less electrical power and heat than the socket's 60W thermal limit. In fully enclosed ceiling globes or tight recessed cans, only install bulbs explicitly labeled Suitable for Enclosed Fixtures so trapped heat does not shorten driver life.
How many lumens do I need to replace 40W, 60W, 75W, and 100W bulbs?
Look for 450 lumens to replace 40W, 800 lumens to replace 60W, 1,100 lumens to replace 75W, 1,600 lumens to replace 100W, and 2,600 lumens to replace 150W. If you are planning brightness for a whole room from scratch, use our Room Lumens & Spacing Calculator.
LED Buyer's Guides by Room & Facility
Browse Residential LED Guides (24) or Commercial & Industrial Guides (7):
Residential Room & Fixture Guides
Commercial & Industrial Facility Guides
- • FTC Energy Labeling Rule (16 CFR Part 305): Lighting Facts Lumen Equivalency
- • U.S. Department of Energy (DOE): General Service Lamp Efficiency Standards
- • DesignLights Consortium (DLC) Commercial Qualified Products List
- • Illuminating Engineering Society (IES) Photometric Testing Standards (LM-79 & LM-80)